EFEKTIFITAS BONDING ATTACHMENT TERHADAP STATUS HEMODINAMIK PADA BAYI DI RUANG PBRT RSUP DR. KARIADI SEMARANG

Kurniasih, Maike, G2A216040 (2018) EFEKTIFITAS BONDING ATTACHMENT TERHADAP STATUS HEMODINAMIK PADA BAYI DI RUANG PBRT RSUP DR. KARIADI SEMARANG. Sarjana / Sarjana Terapan (S1/D4) thesis, ["eprint_fieldopt_institution_Universitas Muhammadiyah Semarang" not defined].

[img]
Preview
Text
MANUSCRIPT..pdf

Download (2MB) | Preview
[img]
Preview
Text
ABSTRAK.pdf

Download (2MB) | Preview
[img]
Preview
Text
BAB I.pdf

Download (2MB) | Preview
[img]
Preview
Text
BAB II.pdf

Download (2MB) | Preview
[img] Text
BAB III.pdf
Restricted to Repository staff only

Download (2MB) | Request a copy
[img] Text
BAB IV.pdf
Restricted to Repository staff only

Download (2MB) | Request a copy
[img]
Preview
Text
BAB V.pdf

Download (2MB) | Preview
[img]
Preview
Text
DAFTAR PUSTAKA.pdf

Download (2MB) | Preview

Abstract

Background: Hemodynamic status is an important parameter for assessing the physiological function of vital organs in newborns. Therefore it is necessary to stabilize the condition of the infant so as not to decrease hemodynamic status, one of them by doing bonding attachment. Based on the observations in the PBRT Room of Dr. Kariadi Hospital, mothers tend to surrender full care after the baby is born to the nurses, whereas the mother's touch after delivery is important, including stabilizing infant hemodynamics. Purpose: To analyze the effectiveness of bonding attachment to infant hemodynamic status in PBRT Room Dr. Kariadi Hospital of Semarang. Research method: One Group Pre-test-Postest Design. The process of this research has been conducted on June 2017 - February 2018 in the room at PBRT Room Dr. Kariadi Semarang, with sampling technique total sampling based on inclusion and exclusion criteria, sample number 37 respondents. Results: Pre-test results showed median pulse rate 102 X / min, respiration 20 X / min, and saturation of baby 92%. Post-test results mean pulse rate 133 X / min, median respiratory value 20 X / min, and saturation of 92% baby oxygen. Suggestion: There are differences in pulse, breathing, and oxygen saturation of babies before and after bonding attachment (p-value = 0.001, 0,000, and 0,000). Suggestion: that nurses provide information, train, and motivate the mothers to do bonding attachment, which has not been done optimally. Keywords : Infant hemodynamic status, bonding attachment References : 30 (2008 – 2017)

Item Type: Thesis (Sarjana / Sarjana Terapan (S1/D4) )
Call Number: 050/S1 Kep/VII/2018
Subjects: R Medicine > RT Nursing
Divisions: Faculty of Nursing and Health > S1 Nursing
Depositing User: perpus unimus
Date Deposited: 18 Jul 2018 07:08
Last Modified: 18 Jul 2018 07:08
URI: http://repository.unimus.ac.id/id/eprint/1881

Actions (login required)

View Item View Item