LAJU PENYUMBATAN PIPA PADA HEAT EXCHANGER TIPE SHELL AND TUBE DAN PENGENDALIANNYA DENGAN ADITIF ASAM FORMAT DAN ASAM OKSALAT

Rozaqi, Fajar, C2A215014 (2018) LAJU PENYUMBATAN PIPA PADA HEAT EXCHANGER TIPE SHELL AND TUBE DAN PENGENDALIANNYA DENGAN ADITIF ASAM FORMAT DAN ASAM OKSALAT. Sarjana / Sarjana Terapan (S1/D4) thesis, ["eprint_fieldopt_institution_Universitas Muhammadiyah Semarang" not defined].

[img]
Preview
Text
Abstrak.pdf

Download (127kB) | Preview
[img]
Preview
Text
BAB I.pdf

Download (184kB) | Preview
[img]
Preview
Text
BAB II.pdf

Download (918kB) | Preview
[img] Text
BAB III.pdf
Restricted to Repository staff only

Download (630kB) | Request a copy
[img] Text
BAB IV.pdf
Restricted to Repository staff only

Download (1MB) | Request a copy
[img]
Preview
Text
BAB V.pdf

Download (152kB) | Preview
[img]
Preview
Text
DAFTAR PUSTAKA.pdf

Download (122kB) | Preview
[img]
Preview
Text
JURNAL.pdf

Download (362kB) | Preview

Abstract

LAJU PENYUMBATAN PIPA PADA HEAT EXCHANGER TIPE SHELL AND TUBE DAN PENGENDALIANNYA DENGAN ADITIF ASAM FORMAT DAN ASAM OKSALAT Disusun oleh : Fajar Rozaqi NIM : C2A215014 Program Studi Teknik Mesin Fakultas Teknik Universitas Muhammadiyah Semarang ABSTRAK Pipa pada Heat Exchanger Shell and Tube didesain dengan diameter relatif kecil dalam usaha mendapatkan efisiensi perpindahan panas yang tinggi. Penampang pipa yang kecil ini menjadikan pipa rawan tersumbat oleh kerak. Beberapa penelitian telah menunjukkan bahwa kerak CaCO3 pada permukaan dalam pipa menghambat proses perpindahan panas menjadi 15 sampai 30 kali lebih rendah. Oleh karenanya perlu dilakukan mitigasi pengendalian kerak CaCO3 dalam pipa heat exchanger. Penelitian mitigasi pengendalian kerak CaCO3 ini dilakukan dengan bahan sintetik yaitu CaCl2.2H2O; Na2CO3 dan asam format (CH2O2) dan asam oksalat (C2H2O4). Sebuah alat eksperimen yang dikendalikan secara otomatis menggunakan program komputer berbasis pada software Delphi 3 yang diproduksi oleh Borland® dilengkapi dengan modul Heat Exchanger Shell and Tube berukuran mini dipasangkan pada alat eksperimen dioperasikan dengan model aliran searah dan berlawanan. Data yang didapat dianalisis menggunakan rumus efisiensi perpindahan panas untuk mengetahui model aliran Heat Exchanger Shall and Tube yang berpotensi paling rendah dalam pembentukan kerak. Kerak selanjutnya dianalisis menggunakan SEM dan XRD dan dianalisis lanjut menggunakan metode kuantitatif analisis Rietzveld refinery dengan program FullProf untuk mengungkap distribusi fase dimana sangat dibutuhkan dalam mitigasi fisik. Selain melakukan mitigasi fisik, penelitian ini juga melakukan mitigasi pengendalian kerak dengan metode kimiawi yaitu dengan menambahkan senyawa kimia asam format (CH2O2) dan asam oksalat (C2H2O4) pada air pengumpan untuk mengendalikan kerak. Eksperimen pengujian penggunaan dua bahan aditif asam format dan asam oksalat dalam pengoperasian Shell and Tube Heat Exchanger dengan model aliran Linear Flow dan Cross Flow telah berhasil dilaksanakan. Model Linear Flow (LF) mengakibatkan pembentukan kerak CaCO3 hanya mencapai 0,9243 gram lebih sedikit dibanding dengan model Cross Flow (CF) mencapai 0,9646 gram. Pada penggunaan asam format 10 ppm massa kerak bisa dikurangi dari 0,9243 gram menjadi 0,6486 gram atau dapat diturunkan sebesar 30%. Penggunaan asam oksalat 10 ppm hanya mampu menurunkan massa kerak menjadi 0,7672 gram atau turun sebesar 18%. Pada eksperiman pengujian, penggunaan asam format sebagai aditif mampu menurunkan laju penyumbatan pipa dari tanpa aditif berkisar 600 jam menjadi 854 jam atau lebih lama sebesar 42,3%. Penggunaan asam oksalat sebagai aditif hanya mampu menurunkan laju penyumbatan pipa berkisar 717 jam atau lebih lama 19,5%. Blockage Rate Pipe on Shell and Tube Heat Exchanger and Controlled with Formic Acid and Oxalic Acid Additives Arranged by: Fajar Rozaqi NIM : C2A215014 Mechanical Engineering Study Program Faculty of Engineering University of Muhammadiyah Semarang ABSTRACT Pipes on Heat Exchanger Shell and Tube are usually designed in smaller diameter in address to achieve higher heat transfer efficiency. This smaller diameter makes the pipes tends to be clogged by the scale. Several studies have been proven that the scale of CaCO3 on the inner surface declined heat transfer process untill 30 times lower. That’s why the research on heat exchanger scale mitigation is very important to con- duct. In this research, mitigation of CaCO3 scale control was done by synthetic mate- rials, namely CaCl2.2H2O; Na2CO3, formic acid (CH2O2) and oxalic acid (C2H2O4). An automatic computer program based on Delphi 3.0 software produced by Borland® equipped to the rig and also a module of Shell and Tube Heat Exchanger. The module was operated in direct and cross flow model. The scale is further analyzed using SEM and XRD and continued by Rietzveld refinery quantitative analysis method assisted by FullProf program to reveal the distribution of phases which are urgently needed in physical mitigation. In addition to physical mitigation, this study also mitigated scale control by chemical methods. Testing experiments on the use of formic acid and oxalic acid additives in the operation of Shell and Tube Heat Exchangers with Linear Flow and Cross Flow flow models have been successfully implemented. Scale deposited of Linear Flow (LF) model resulted CaCO3 scale only 0.9243gram other wise Cross Flow (CF) model 0.9646 gram. The use formic acid in 10 ppm reduced scale deposited from 0.9243 gram to 0.6486 gram or decreased 30%. The use 10 ppm oxalic acid only able decreased scale deposited to 0.7672 gram or decreased by 18%. The use of formic acid is able to alter the crystal phase distribution convincingly where the vaterite phase appears in the amount of 50% of the original only 32%. This vaterite phase has an effect in decreasing crustal mass because this phase has the lowest density. At the test experiment, the use of formic acid as an additive can reduce the pipe blockage rate from without additives ranging from 600 hours to 854 hours or longer by 42.3%. The use of oxalic acid as an additive can only reduce the pipe blockage rate of 717 hours or longer by 19.5%

Item Type: Thesis (Sarjana / Sarjana Terapan (S1/D4) )
Contributors Thesis: 1. Drs. H. Samsudi Raharjo, ST. MT. MM 2. Rubijanto Juni Pribadi, ST. MT
Subjects: T Technology > TJ Mechanical engineering and machinery
Divisions: Faculty of Engineering > S1 Mechanical Engineering
Depositing User: perpus unimus
URI: http://repository.unimus.ac.id/id/eprint/3130

Actions (login required)