PERBEDAAN BERAT JENIS CAIRAN PLEURA CARA HIDROMETER DAN DIPSTIK

Utami, Eni Sri Budi, G0C214055 (2017) PERBEDAAN BERAT JENIS CAIRAN PLEURA CARA HIDROMETER DAN DIPSTIK. Diploma III thesis, ["eprint_fieldopt_institution_Muhammadiyah University of Semarang" not defined].

[img]
Preview
Text
Abstrak.pdf

Download (322kB) | Preview
[img]
Preview
Text
BAB_1_Pendahuluan.pdf

Download (330kB) | Preview
[img]
Preview
Text
BAB_II_Tinjauan_Pustaka.pdf

Download (477kB) | Preview
[img] Text
BAB_III_Metode_Penelitian.pdf
Restricted to Repository staff only

Download (331kB) | Request a copy
[img] Text
BAB_IV_Hasil_Penelitian_dan_Pembahasan.pdf
Restricted to Repository staff only

Download (334kB) | Request a copy
[img]
Preview
Text
BAB_V_Simpulan_dan_Saran.pdf

Download (277kB) | Preview
[img]
Preview
Text
DAFTAR_PUSTAKA.pdf

Download (320kB) | Preview

Abstract

Diagnostic test of pleural fluid density can be conducted through hydrometer and dipstick methods. The hydrometer method uses the scale between 1,000 and 1,060 (with calibrating temperature of 20 C), while the dipstick method uses the scale of colors. This research is aimed to distinguish pleural fluid density through those two methods. This research constitutes analytical research. Samples were taken from random sampling technic within total population of hospitalized patients at RSUP Dr.Kariadi during November 2016 to December 2016. Samples were both checcked by hydrometer and dipstick test. Samples that cannot meet the requirements were excluded, so that the research undertook 61 samples. Data collections were analyzed with Kolmogorov-Smirnov then continued with Wilcoxon test. As the result, the diagnostic tests have measured an average score of the hydrometer amounted to 1,023, and 1,013 with the dipstick method. These results show that the density measurement of pleural fluid with the hydrometer is higher than the dipstick. Normality data test using Kolmogorov-Smirnov concludes that the data is not well distributed (p<0,001). Furthermore, non-parametric study of the Wilcoxon test indicates that both tests had a significant variation (p<0,001). The research concludes that there was distinction of pleural fluid diagnostic with the hydrometer and the dipstick methods. Keywords: Diagnostic test, Pleural fluid density

Item Type: Thesis (Diploma III)
Call Number: 059/D3.ana/V/2017
Subjects: Q Science > Q Science (General)
Divisions: Faculty of Nursing and Health > D3 Health Analyst
Depositing User: perpus unimus
URI: http://repository.unimus.ac.id/id/eprint/407

Actions (login required)

View Item View Item