PERBEDAAN KADAR PROTEIN PADA LIQUOR CEREBRO SPINALIS MENGGUNAKAN METODE AUTOMATIC ANALYZER DAN CARIK CELUP

Cahyani, Umi, G0C214058 (2017) PERBEDAAN KADAR PROTEIN PADA LIQUOR CEREBRO SPINALIS MENGGUNAKAN METODE AUTOMATIC ANALYZER DAN CARIK CELUP. Diploma III thesis, ["eprint_fieldopt_institution_Muhammadiyah University of Semarang" not defined].

[img]
Preview
Text
abstrak.pdf

Download (255kB) | Preview
[img]
Preview
Text
KTI bagian isi bab 1.pdf

Download (257kB) | Preview
[img]
Preview
Text
KTI bagian isi bab 2.pdf

Download (297kB) | Preview
[img] Text
KTI bagian isi bab 3.pdf
Restricted to Repository staff only

Download (414kB) | Request a copy
[img] Text
KTI bagian isi bab 4.pdf
Restricted to Repository staff only

Download (267kB) | Request a copy
[img]
Preview
Text
KTI bagian isi bab 5.pdf

Download (248kB) | Preview
[img]
Preview
Text
KTI daftar pustaka.pdf

Download (248kB) | Preview

Abstract

Protein content in LCS can be done by automatic analyzer and dye. The automatic analyzer tool is not all in the program for LCS inspection but the LCS check is often done with the automatic method. The purpose of the examination is to compare the automatic analyzer method and the dye strip. The type of research is analytical research. Sample 39 was obtained from outpatient and in-patient of RSUP dr. Kariadi Semarang during August 2016 - February 2017 as many as 39 samples taken according to inclusion and exclusion criteria. Data were tested by Wilcoxson test and Kappa test. The result of LCS protein automatic analyzer method was converted to semi-quantitative with mean of 109.3 mg / dl positive 3 (+3), highest of 720,1 mg / dl positive 4 (+4) and lowest 6,8 mg / dl negative (-) , Whereas in the dye method obtained the lowest negative result (-), the highest positive value 3 / (+++). Different test using Wilcoxon test showed significance value 0,243; <0,05 and test of suitability of Kappa test showed value of conformity 0,337; P <0.001. The result of LCS protein concentration showed that there is no difference between automatic analyzer method and dye filter, so the dye method can be used as an alternative for LCS protein content. Keywords: Liquor Cerebrospinalis (LCS), Automatic Analyzer, strip dye

Item Type: Thesis (Diploma III)
Call Number: 016/D3.ana/V/2017
Subjects: Q Science > Q Science (General)
Divisions: Faculty of Nursing and Health > D3 Health Analyst
Depositing User: perpus unimus
Date Deposited: 19 Jul 2017 08:11
Last Modified: 31 Jan 2018 02:32
URI: http://repository.unimus.ac.id/id/eprint/470

Actions (login required)

View Item View Item