PERBEDAAN JUMLAH LEUKOSIT PADA SEDIMEN URIN DENGAN METODE MANUAL DAN OTOMATIS SYSMEX UF-1000i

Fidiyah, Inna Nur, G0C214054 (2017) PERBEDAAN JUMLAH LEUKOSIT PADA SEDIMEN URIN DENGAN METODE MANUAL DAN OTOMATIS SYSMEX UF-1000i. Diploma III thesis, ["eprint_fieldopt_institution_Muhammadiyah University of Semarang" not defined].

[img]
Preview
Text
3. Abstrak.pdf

Download (327kB) | Preview
[img]
Preview
Text
4. bab 1.pdf

Download (341kB) | Preview
[img]
Preview
Text
5. bab 2.pdf

Download (544kB) | Preview
[img] Text
6. bab 3.pdf
Restricted to Repository staff only

Download (446kB) | Request a copy
[img] Text
7. bab 4.pdf
Restricted to Repository staff only

Download (342kB) | Request a copy
[img]
Preview
Text
8. bab 5.pdf

Download (324kB) | Preview
[img]
Preview
Text
9. Daftar pustaka.pdf

Download (910kB) | Preview

Abstract

Examination of leukocytes counts in urine sediment can be done by manual microscopic and automatic methods. Both methods are used for urine sediment in all patients either outpatient or inpatient at dr. Kariadi Semarang. Differences in the results of these two methods into the background issues in research. The purpose is to compare the results of WBC counts in urine by both manual microscopic and automatic methods using flowcytometri-based Sysmex UF-1000i. This is an analytical research. Samples were randomly taken from total population of outpatient and inpatient dr. Kariadi during the month of November 2016 and performed by automatic cell counting using the Sysmex UF-1000i. Samples were not eligible were excluded so as to get the total sample of 28. The data value was analyzed by Shapiro Wilk test followed by Wilcoxon. The statistical showed the average examination results using automatic analysis was 7/LPB with a SD of 7.43 ± 9.92, while manually 8 / LPB with a SD of 5.57 ± 6.60. It suggested the manual counting leukocyte counts are higher than automatic counts. Wilcoxon test results showed a difference between the amount of urine leukocytes of both methods with p <0.001. The conclusion from this study is there a significant difference between the examination of urine leukocytes with manual microscopy methods, and automatic Sysmex UF-1000i. Keywords: examination methods, leukocyte counts in urine

Item Type: Thesis (Diploma III)
Call Number: 004/D3.ana/V/2017
Subjects: Q Science > Q Science (General)
Divisions: Faculty of Nursing and Health > D3 Health Analyst
Depositing User: perpus unimus
URI: http://repository.unimus.ac.id/id/eprint/426

Actions (login required)

View Item View Item