PENGARUH ANTIKOAGULAN K3DTA DAN HEPARIN VAKUNTAINER TERHADAP JUMLAH TROMBOSIT DENGAN METODE AUTOMATIK

Arningsih, Wahyuni, G1C013019 (2017) PENGARUH ANTIKOAGULAN K3DTA DAN HEPARIN VAKUNTAINER TERHADAP JUMLAH TROMBOSIT DENGAN METODE AUTOMATIK. Sarjana / Sarjana Terapan (S1/D4) thesis, ["eprint_fieldopt_institution_Universitas Muhammadiyah Semarang" not defined].

[img]
Preview
Text
ABSTRAK.pdf

Download (468kB) | Preview
[img]
Preview
Text
BAB I.pdf

Download (584kB) | Preview
[img]
Preview
Text
BAB II.pdf

Download (896kB) | Preview
[img] Text
BAB III.pdf
Restricted to Repository staff only

Download (670kB) | Request a copy
[img] Text
BAB IV.pdf
Restricted to Repository staff only

Download (643kB) | Request a copy
[img]
Preview
Text
BAB V.pdf

Download (486kB) | Preview
[img]
Preview
Text
DAFTAR PUSTAKA.pdf

Download (520kB) | Preview

Abstract

Jumlah Trombosit merupakan banyaknya trombosit dalam darah yang diukur dengan alat hematologi anlizer merk Bc 2600 yang dinyatakan sebagai platelet ( PLT) dengan darah antikoagulan K3DTA dan Heparin Vakuntainer. K3DTA merupakan antikoagulan yang mencegah koagulasi dengan cara mengikat kalsium yang dapat menyebabkan agregasi trombosit, karena agregasi trombosit tergantung adanya kalsium bebas di plasma sedangkan Heparin vakuntainer menghambat pembentukan dan aktivitas thrombin melalui ikatan dengan antitrombin III dan dapat dipakai untuk pemeriksaan trombosit yang tidak mempengaruhi bentuk dan jumlah trombosit. Tujuan penelitian ini mengetahui pengaruh antikoagulan K3DTA dan Heparin vakuntainer terhadap jumlah trombosit dengan metode automatik . Metode penelitian ini dilakukan di laboratorium Klinik Universitas Muhammadiyah Semarang pada bulan januari 2017. Sampel Penelitian adalah mahasiswa program studi DIV Analis Kesehatan Semester VII Universitas Muhammadiyah Semarang yang dipilih secara acak. Hasil uji statistik menunujukan bahwa antikoagulan K3DTA dan heparin vakuntainer terhadap jumlah trombosit ada pengaruh yang signifikan karena adanya perbedaan rata-rata 215000,00 mm3/sell jumlah trombosit dengan K3DTA, sedangkan Heparin vakuntainer dengan nilai rata-rata 257312,50 mm3/sell.). Kesimpulan: Terdapat pengaruh yang signifikan antikoagulan K3DTA dengan Heparin vakuntainer terhadap jumlah trombosit. Kata Kunci : Jumlah Trombosit, Antikoagulan K3DTA, Heparin vakuntainer. Platelet count is the number of platelets in the blood as measured by ankle hematologic device brand Bc 2600 expressed as platelet (PLT) with blood anticoagulant K3DTA and Heparin Vakuntainer. K3DTA is an anticoagulant that prevents coagulation by binding calcium which can cause platelet aggregation, since platelet aggregation depends on the presence of free calcium in plasma whereas Heparin vakuntainer inhibits thrombin formation and activity by bonding with antithrombin III and can be used for platelet examination that does not affect the shape and Platelet count.The purpose of this study To determine the effect of anticoagulant K3DTA and Heparin vakuntainer against the number of platelets with automatic method. This research method is done in laboratory Clinic University of Muhammadiyah Semarang in january 2017. The sample of research is student of DIV of Medical Analyst of Semester VII University of Muhammadiyah Semarang chosen at random. The results of the statistical test showed that K3DTA anticoagulant and heparin vaccuntainer to platelet counts were significantly influenced by the difference of 215000,00 mm3 / tons platelet count with K3DTA, while Heparin vakuntainer with an average value of 257312.50 mm3 / sell. ). Conclusion: There is a significant effect of K3DTA anticoagulation with Heparin vaccuntainer against platelet count. Keywords: Platelet count, anticoagulant K3DTA, Heparin vacutainer.

Item Type: Thesis (Sarjana / Sarjana Terapan (S1/D4) )
Subjects: R Medicine > Health Analyst
Divisions: Faculty of Nursing and Health > D4 Health Analyst
Depositing User: perpus unimus
URI: http://repository.unimus.ac.id/id/eprint/1158

Actions (login required)

View Item View Item